CVM is a rugged waterproof design dual frequency sounder type. HF channel frequency range 100KHz-340KHz, suitable for shallow water survey and side-scan measurements. Low-frequency channel range is 24KHz-50KHz. With greater depth and for measuring fluid mud detection. Because of broadband frequency input, CVM compatible with a variety of new and existing transducer.
Key performance indicators
◆ Operating Frequency
LF: 24 - 50 kHz
High frequency: 100 - 340 kHz
Frequency adjustment step size: 1 kHz
◆ odometry
0.5 - 600 m @ 33 kHz
0.2 - 200 m @ 210 kHz
◆ Output Power
LF: 420 W RMS
High frequency: 350 W RMS
◆ Accuracy
0.10 m ± 0.1% depth @ 33 kHz
0.01 m ± 0.1% depth @ 200 kHz
◆ Resolution
0.01 m
◆ phase adjustment
Automatic or manual adjustment of 30%, 20%, 10% superposition
◆ tagging content
Internal automatic annotation: date, time, location
External dimension: via RS232 interface input
◆ Communication Interface
2x RS232
Input data: DGPS, heave compensation swell
Output data format: NMEA 0183, DESO 25, Odom and depth of analog image data output through an Ethernet port